installing
the TCO in the chamber and gradually increasing
temperature up to the 20 ¡É lower than Tf, then
if the temperature of the chamber and the testing
products and made equal. the temperature is increased
1¡É per minute, then the fuse will be function
within the specified tolerance.
|

|
when the
working voltage and current are applied the TCO
in ambient temperature, 20~25 ¡É, the temperature
of the TCO will go up. But the increase of temperature
shall be not more than 10 ¡É.
|

|
After
having operated in temperature test of section 1,
the insulation resistance shall be more then
0.2 §Û when tested with 500V resistance measuring
machine.
|

|
The resistance
of the both leads of the TCO should not exceed 1.5§Û
within the 10mm length of the leads. |

|

|
After
conducting the Insulation resistance test, section
3, the TCO shall be maintain without breakdown
when AC 500V is applied between the leads of the
TCO for 1 Min.
|

|
after
keeping the TCO in the chamber with humidity 90~95%
and specified below condition for 500 hours,
the TCO shall be tested Functioning temperature
test, section 1.
|
| Tf |
chamber temperature |
humidity |
| 100 ¡É less |
40 ± 2 ¡É |
90~95% |
| 100 ¡É over |
65 ± 2 ¡É |
|

|
after
keeping the TCO at the temperature 20 ± 3
¡É lower then the Tf for 48 hours, the TCO
shall be tested Functioning temperature test, section
1.
|

|
|

|